雙足平衡測(cè)痛儀(雙足平衡法測(cè)試,Incapacitance Analgesia Test)測(cè)試評(píng)估大鼠或小鼠后肢的痛覺(jué)和發(fā)炎,測(cè)量精準(zhǔn)。
雙足平衡法測(cè)痛儀用于對(duì)大鼠或小鼠后肢的痛覺(jué)和發(fā)炎測(cè)試評(píng)估,克服了其它測(cè)試方式可能引起的動(dòng)物緊張或主觀性問(wèn)題,該技術(shù)采用雙通道重量平均法,可以同時(shí)對(duì)一只動(dòng)物進(jìn)行控制和測(cè)試,可選購(gòu)大鼠或小鼠兩種型號(hào)。
雙足平衡測(cè)試法(Incapacitance Analgesia Meter)可以自動(dòng)并且是可重復(fù)的評(píng)估止痛效果。它可測(cè)量體重在小動(dòng)物后肢分配情況,每個(gè)肢體對(duì)感應(yīng)器施加的力量,在選定的時(shí)間周期內(nèi)的平均值,可以表現(xiàn)受試對(duì)象從一邊到另一邊的抬起足部,因此可以提供量化的體重在后肢的平衡分配。
型號(hào)600MR
雙足平衡法測(cè)痛儀主要特點(diǎn)
· 適用于大鼠、小鼠
· 采用精確的可編程數(shù)字控制
· 帶動(dòng)物反應(yīng)自動(dòng)檢測(cè)功能
· 手動(dòng)覆蓋所有計(jì)時(shí)器功能
· 數(shù)字式顯示
· 鍵盤(pán)輸入各種參數(shù)
· 配備腳踏開(kāi)關(guān)
· 可選配軟件通過(guò)USB接口連接電腦(可選)
部分參考文獻(xiàn)
Evaluation of liposome-encapsulated butorphanol tartrate for alleviation of experimentally induced arthritic pain in green-cheeked conures (Pyrrhura molinae)
JR Paul-Murphy, LA Krugner-Higby… - American journal of …, 2009 - Am Vet Med Assoc
... f. Paralube, Fougera, Melville, NY. g. IITC model 600 incapacitance meter, IITC Life
Science, Woodland, Calif. h. Canon Optura 40, Canon USA Inc, Lake Success, NY. i.
Windows Movie Maker, version 2.1, Microsoft Corp, Redmond, Wash. ...
[HTML] Hyperalgesia, synovitis and multiple biomarkers of inflammation are suppressed by interleukin 1 inhibition in a novel animal model of gouty arthritis
R Torres, L MacDonald, SD Croll, J Reinhardt… - Annals of the …, 2009 -
... The results are presented as the percentage change from the baseline readings. To test
willingness to bear weight on injected ankles, the weightbearing test was performed using an
Incapacitance meter (model 600, IITC Life Sciences, Woodland Hills, California, USA). ...
Analgesic effects of carprofen and liposome-encapsulated butorphanol tartrate in Hispaniolan parrots (Amazona ventralis) with experimentally induced arthritis
JR Paul-Murphy, KK Sladky… - American journal of …, 2009 - Am Vet Med Assoc
... d. Rimadyl injectable, 50 mg/mL, Pfizer Animal Health, Exton, Pa. e. IITC model 600 incapacitance meter, IITC Life Science, Woodland, Calif. f. Canon Optura 40, Canon USA Inc, Lake Success, NY. g. Saint Louis Zoo Endocrinology Lab, Saint Louis Zoo, St Louis, Mo. ...
Analgesic effects of intramuscular administration of meloxicam in Hispaniolan parrots (Amazona ventralis) with experimentally induced arthritis
GA Cole, J Paul-Murphy… - American journal of …, 2009 - Am Vet Med Assoc
... d. 0.9% sodium chloride injection, USP, Hospira, Lake Forest, Ill. e. IITC Incapacitance Meter, model 600, IITC Life Science, Woodland Hills, Calif. f. 24A-D Series parallel Shaft DC Gearmoter, model 0194, serial No. 0194JTE0015, Bodine Electric Co, Chicago, Ill. ...
[PDF] Kinematic and dynamic gait compensations resulting from knee instability in a rat model of osteoarthritis
KD Allen, BA Mata, MA Gabr, JL Huebner… - Arthritis Res …, 2012 -
... weight distribution was measured on an inca- pacitance meter (IITC, Inc., Woodland Hills, CA, USA), a behavioral analysis assay that measures weight bearing on the hindlimbs while the animal is in an induced rear- ing posture [10]. In brief, an incapacitance meter con- sists of ...
Single intrathecal administration of the transcription factor decoy AYX1 prevents acute and chronic pain after incisional, inflammatory, or neuropathic injury
J Mamet, M Klukinov, TL Yaksh, SA Malkmus… - PAIN®, 2014 - Elsevier
... In the SNI and the knee surgery models, incapacitance was measured as the difference in static weight bearing between the ipsilateral versus contralateral hind paw relative to the injury using an incapacitance meter (model 600; IITC Life Science, Woodland Hills, CA). ...
[PDF] Efficacy of an equine joint supplement, and the synergistic effect of its active ingredients (chelated trace minerals and natural eggshell membrane), as …
KJ Wedekind, A Josie, J Zhao - 2015 -
... A Hamilton PB 600-1 repeating dispenser (model 750; Hamilton Company, Reno, NV, USA) with a 700 series luer tip microliter syringe was used for precise injection ... An incapacitance tester (IITC Life Science, Woodland Hills, CA, USA) was used to measure weight distribution. ...
[HTML] Behavioral, medical imaging and histopathological features of a new rat model of bone cancer pain
L Doré-Savard, V Otis, K Belleville, M Lemire… - PLoS One, 2010 - dx.plos.org
... Static weight bearing was measured using the Incapacitance Meter (IITC Life Science, Woodland Hills, CA, USA). ... The results obtained with the incapacitance meter were used as a control for a second ... A 600-µl bolus of contrast agent (Gd-DPTA, Magnevist, Berlex) was injected ...
,