LWGY series turbine flow meters have the features: high accuracy, good repeatability, convenient installation/maintenance, simple structure etc.… ……………………………….
Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.
Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact CHENGFENG FLOWMETER.………………………
Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized product’s specification. 2. SPECIFICATION Performance Repeatability: ±0.2% Accuracy: Standard:±1% of reading; Optional:±0.5% of reading Wetted Components Housing: Standard:304SS; Optional:316SS Bearings and Shaft: Tungsten Carbide Rotor: Standard-2Cr13 Stainless Steel (Optional Alloy CD4Mcu) Retaining Rings: 316 Stainless Steel Output Signal:(Where applicable) Sensor: Pulse signal(Low level:≤0.8V,High level≥8V) Transmitter: 4 to 20 mA DC current signal Signal Transmission Distance:≤1000m Electric Connections: Basic Type: Hausman connector or Three core cable Explosion Proof Type: ISO M20×1.5 Female Explosion Proof Level: Standard: None ; Optional: ExdIIBT6 Protection Level: IP65 3. OPERATION CONDITIONS Ambient: Temperature: -10℃ to +55℃ Pressure: 86 to 106KPa Relative Humidity: 5% to 90% Power Supply: Sensor: +12V DC(Optional:+24V DC) Transmitter: +24V DC Field Display Type B: Integral 3.2V Lithium Battery(Others available on request) Field Display Type C: +24V DC Fluid Temperature and Pressure: Temperature: -20℃ to +110℃ Pressure: Fluid pressure should be limited according to rating. Measurable Flow Rate Range and Pressure Level:(See table 1) Table 1.Measurable Flow Range and Pressure Rating
Nominal Diameter
Standard Flow Range (SFR)
Extended Flow Range (EFR)
Standard Pressure Rating
Customized Pressure Rating
(mm)
(in.)
(m3/h)
(m3/h)
(MPa)
(MPa)-Flange fitting
4
0.15
0.04~0.25
0.04~0.4
Thread:6.3
12,16,25
6
0.25
0.1~0.6
0.06~0.6
Thread:6.3
12,16,25
10
0.4
0.2~1.2
0.15~1.5
Thread:6.3
12,16,25
15
0.5
0.6~6
0.4~8
Thread:6.3;Flange:2.5
4.0,6.3,12,16,25
20
0.75
0.8~8
0.45~9
Thread:6.3;Flange:2.5
4.0,6.3,12,16,25
25
1
1~10
0.5~10
Thread:6.3;Flange:2.5
4.0,6.3,12,16,25
32
1.25
1.5~15
0.8~15
Thread:6.3;Flange:2.5
4.0,6.3,12,16,25
40
1.5
2~20
1~30
Thread:6.3;Flange:2.5
4.0,6.3,12,16,25
50
2
4~40
2~40
Flange:2.5
4.0,6.3,12,16,25
65
2.5
7~70
4~70
Flange:2.5
4.0,6.3,12,16,25
80
3
10~100
5~100
Flange:2.5
4.0,6.3,12,16,25
100
4
20~200
10~200
Flange:1.6
4.0,6.3,12,16,25
125
5
25~250
13~250
Flange:1.6
2.5,4.0,6.3,12,16
150
6
30~300
15~300
Flange:1.6
2.5,4.0,6.3,12,16
200
8
80~800
40~800
Flange:1.6
2.5,4.0,6.3,12,16
Model Selection(See Table 2) Table 2.Model Selection Guidance