當(dāng)前位置:東譜科技(廣州)有限責(zé)任公司>>>>全新Duetta熒光和吸收光譜儀

全新Duetta熒光和吸收光譜儀

返回列表頁
參  考  價面議
具體成交價以合同協(xié)議為準(zhǔn)

產(chǎn)品型號

品       牌

廠商性質(zhì)其他

所  在  地廣州市

聯(lián)系方式:查看聯(lián)系方式

更新時間:2024-05-31 08:31:51瀏覽次數(shù):126次

聯(lián)系我時,請告知來自 環(huán)保在線


    暫無信息


    暫無信息

經(jīng)營模式:其他

商鋪產(chǎn)品:70條

所在地區(qū):

產(chǎn)品簡介

Duetta二合一系統(tǒng)不需要多臺掃描儀

詳細(xì)介紹

Duetta二合一系統(tǒng)不需要多臺掃描儀。 除了傳統(tǒng)的熒光和吸收光譜模式,該系統(tǒng)還具有同時吸收-透射熒光激勵發(fā)射矩陣(A-TEEM),由于自動進(jìn)行內(nèi)部濾波效應(yīng)校正,因此可以提供更好的分子指紋和擴(kuò)展的動態(tài)范圍。


A Better Spectrometer Concept


Simultaneous Fluorescence and Absorbance Spectrometer

  • UV-Vis-NIR Fluorescence Detection Wavelength Range from 250 to 1,100 nm
  • Full 3-D Fluorescence EEM Acquisition in Less Than One Second
  • Best in Class Fluorescence Sensitivity Specification of 6,000:1 RMS for Water Raman
  • Automatic Correction for Primary and Secondary Inner Filter Effects (IFE)
  • High Fidelity Molecular Fingerprinting with Unique A-TEEM™
    (Absorbance-Transmittance Excitation Emission Matrix) Technology

  • Millisecond CCD Detection of Entire Fluorescence Spectrum

Simultaneous Fluorescence and Absorbance in one Spectrometer!

Duetta can be used as a fluorometer, as a UV-Vis-NIR spectrometer to measure absorbance, or as an instrument that measures true molecular fingerprints, which require the simultaneous acquisition of fluorescence and absorbance, correcting for IFE in real time.

Fluorescence in the Blink of an Eye!

Duetta’s ultra-fast, state-of-the-art CCD technology allows it to outperform, by orders of magnitude, any competitor using PMTs. It’s the fastest bench-top fluorometer in the world, and the only fluorometer that can acquire a full spectrum in less than 100 milliseconds! This state-of-the-art CCD technology also extends NIR wavelength detection to 1,100 nm, well beyond the limit of a standard PMT fluorometer.

Highest Fluorescence Sensitivity in its Class

Having the highest level of fluorescence sensitivity means that Duetta’s optimized design lets you measure lower concentrations of sample, and provides better quality of data.

EzSpec™ Touch-Screen Software!

Duetta debuts HORIBA’s new generation software interface with touch-screen utility, and a selection of Apps for routine analysis.


具體參數(shù):


DuettaDuetta-Bio
Acquisition ModesSimultaneous Absorbance and Fluorescence Spectrometer
Fluorescence SensitivitySNR >6,000:1 RMS, 350 nm excitation, 5 nm slits
Spectral Acquisition Rate510,000 nm/min
EEM Acquisition RateAs fast as 1 second (sample and wavelength dependent)
A-TEEM Acquisition RateAs fast as 30 seconds (sample and wavelength dependent)
Fluorescence DetectorCCD/Spectrograph
Fluorescence Detector Range250-1,100 nm
Fluorescence Bandwidth1, 2, 3, 5,10, 20 nm (excitation and emission)
Absorbance DetectorSilicon Photodiode
Absorbance Detector Range250-1,000 nm
Absorbance Bandwidth1, 2, 3, 5,10, 20 nm
Light Source75 W Xenon arc lamp. Dedicated cartidge for snap-in replacement
Excitation/Absorbance Wavelength Range250-1,000 nm
Absorbance Accuracy+/- 0.02 A
Absorbance Range0-2 A
Computer RequirementsWindows 10/8/7 Laptop or PC with 1 USB
SoftwareEZSpec
Dimensions (W x D x H)17 x 20.4 x 14.4 inches; 43.18 cm x 51.816 cm x 36.576
Weight45 pounds; 20.4 kg
Polarizers (Time of Purchase)Not AvailableYes (280 to 750 nm)


附件:Duetta_brochure英文手冊

其他推薦產(chǎn)品更多>>

感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://m.kytsldc.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~