Sol3A Class AAA Solar Simulators 太陽光模擬器

詳細介紹

Sol3A Class AAA Solar Simulators 太陽光模擬器

Leveraging over 40 years of experience in light source and power supply design, Newport’s Oriel® brand is proud to introduce the latest innovation in solar
simulators – the Oriel Sol3A™ Class AAA Solar Simulator family. The product family includes:

Model 94123A = 12 x 12 inch Beam Size
Model 94083A = 8 x 8 inch Beam Size
Model 94063A = 6 x 6 inch Beam Size
Model 94043A = 4 x 4 inch Beam Size
Model 94023A = 2 x 2 inch Beam Size

All Oriel Sol3A solar simulators are certified to IEC 60904-9 Edition 2 (2007), JIS C 8912, and ASTM E927-5 standards for Spectral Match, Non-Uniformity of
Irradiance, and Temporal Instability of Irradiance. By convention, Class AAA is reported with the first letter representing Spectral performance, the second
letter Uniformity of Irradiance, and the third letter Temporal Stability. The Oriel SOL 3A solar simulators all use a single lamp design to meet not one or two, but
all three performance criteria without compromising the 1 Sun output power, providing true Class AAA performance. The Oriel Sol3A uses a black non-
reflective finish to minimize stray light and incorporates captive screws for all panels requiring user access to facilitate lamp replacement, alignment, and filter
changes. Safety interlocks prevent inadvertent exposure to UV light. The Oriel Sol3A rugged design is backed by the Newport Corporation''s world wide
organization.

Why Class AAA?

Photovoltaic (PV) cell research and manufacturing are evolving at an amazing rate, with new technologies like thin film processes, tandem junction and multi-junction cells, organic thin films and dye sensitized cells all requiring careful evaluation of their performance. The old designation of “Class A" solar simulators had become standard in most test laboratories and manufacturing environments, but the definition of Class A has degraded to mean a system that is capable of meeting any one (typically spectral match) of the three performance parameters called out in the test methods. In October 2007 the IEC revised the method used to evaluate the performance of a solar simulator. The new standard calls for quantifying and reporting the performance of each of three performance criteria separately. A solar simulator is now measured as class A, B, or C for Spectral Match, Non-Uniformity of Irradiance, and Temporal Instability of Irradiance. The new Sol3A solar simulators have been designed to meet Class A performance for all 3 of the test requirements, Spectral Match, Non-Uniformity of Irradiance, and Temporal Instability of Irradiance as called out by IEC 60904-9 Edition 2 (2007) edition, JIS C 8912, and ASTM E 927-05.

By ensuring measurement uniformity that allows results comparability and traceability, Class AAA systems reduce binning variability of photovoltaic cell testing as compared to so called Class A, Class B or non-classified sources. This performance consistency allows for precise comparison of performance data for researchers engaged in developing novel solar materials.
Newport Corporation puts each Oriel Sol3A™ through rigorous testing for all 3 standards (IEC, STM, and JIS) to insure compliance and supplies a certificate of calibration for all three standards.

Defining Class AAA Performance Standards

Photovoltaic standards mandate that Class AAA solar simulators meet demanding requirements in three key performance areas: spectral match to the solar spectrum, spatial non-uniformity of irradiance, and temporal instability of irradiance.
There are three standards that define solar simulator performance.

  • IEC 60904-9 Edition 2 (2007) Photovoltaic Devices – Part 9: Solar Simulator Performance Requirements

  • JIS C 8912-1998, Solar Simulators for Crystalline Solar Cells and Modules

  • ASTM E 927-05 (2005) Specification for Solar Simulation for Terrestrial PV Testing

Table 1 Class AAA Standards and Specifications

OrganizationIECJISASTM
Performance Parameter60904-9-2007C 8912E92-05
Spectral Match
(fraction of ideal percentage)
0.75 - 1.250.75 - 1.250.75 - 1.25
Non-Uniformity of Irradiance2.0%2%
Temporal Instability0.5% STI2%


Spectral Match

The standards define the spectral match of a solar simulator as a percentage of the integrated intensity in 6 spectral ranges (listed in Table 2). Any deviation from the specified percentages must then lie within a range that determines the class of the simulator. For Class AAA, this range is 0.75 to 1.25 times the ideal percentage.

Spectral Match

Table 2 Ideal Spectral Match Defined by IEC Standards

Spectral Range (nm)Total Irradiance Range (%)Ideal %
400 - 50013.9 - 23.118.5
500 - 60015.1 - 25.120.1
600 - 70013.7 - 22.918.3
700 - 80011.1 - 18.514.8
800 - 9009.2 - 15.312.2
900 - 110012.1 - 20.116.1


Fig. 1 Oriel Sol3A Spectral Match with AM 1.5G
spectral correction filter meets IEC, JIS, ASTM Class A
requirements to for spectral match.

Spatial Uniformity of Irradiance

The irradiance uniformity over the work area is the most difficult Class AAA requirement to achieve and maintain. Hot spots can lead to significant errors in measured cell efficiency and can cause inaccurate binning of cells. The Class AAA spatial non-uniformity performance standard is designed to minimize the impact of hot spots and has a very stringent requirement of ≤2%. The plot below shows the uniformity of the irradiance across a typical simulator working area. Each unit will come with a plot of irradiance non-uniformity. The working distance ranges for each simulator are listed in Table 3.

Sol3A Working Distances

Table 3 Working Distances

ModelSizeWorking Distance Range (Inches)
94023A2 x 2 (50.8 x 50.8)12.0 ±0.5
94043A4 x 4 (101.6 x 101.6)4.0 ±0.5
94063A6 x 6 (152.4 x 152.4)5.0 ±0.5
94083A8 x 8 (203.2 x 203.2)15.0 ±0.5
94123A12x12 (304.8 x 304.8)



感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://m.kytsldc.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
午夜福利院免费在线观看-久久精品日产第一区二区三区画质| 亚洲一区二区三在线观看-国产精品亚洲а∨天堂123| 国产精品v欧美精品v日韩精品-国产欧美日韩精品区一区二污污污| 亚洲黄片三级三级三级-国产成人一区二区在线视频| 亚洲黑人欧美一区二区三区-亚洲一区二区三区免费视频播放| 亚洲国产欧美日韩不卡-熟妇激情一区二区三区| 精品国产综合一区二区三区-蜜臀一区二区三区刺激视频| 亚洲黑人欧美一区二区三区-亚洲一区二区三区免费视频播放| 狠狠狠狠爱精品一二三四区-l舌熟女av国产精品| 国产一区二区无套内射-国内精品久久久久久久齐pp| 欧美精品啪啪人妻一区二区-嫩草人妻舔舔羞羞一区二区三区| 久久影视av一区二区-人妻激情乱偷一区二区三区| 日韩精品一区二区三区粉嫩av-欧美亚洲国产中文字幕| 人妻互换精品一区二区-夜夜爽一区二区三区视频| 欧美一级一线在线观看-亚洲一区二区亚洲三区| 久久精品亚洲无中文东京热-日本妹子内谢视频一区| 99久热精品免费观看四虎-亚洲天堂精品视频在线| 久久亚州天堂一区二区-色噜噜色哟哟一区二区三区| 久久久国产精品电影片-精品孕妇人妻一区二区三区| 九九热这里只有精品九九-欧美日韩人妻精品一二三| 亚洲一区二区少妇激情-国产精品美女久久高潮| 精品老熟妇一区二区三区-日韩丰满一区二区三区| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 极品人妻av在线播放-久久精品视频一区二区三区| 欧美日韩国产亚洲免费-肉体粗喘娇吟国产91| 婷婷六月视频在线观看-久久亚洲综合国产精品| 国产免费高清av在线播放-成年人在线播放中文字幕| mm在线精品视频在线观看-欧美国产日韩在线一区二区三区| 亚洲av综合av一区东京热-黄页免费视频网站在线观看| sobo欧美在线视频-免费av网址一区二区| 亚洲另类熟女国产精品-懂色一区二区三区在线播放| 丝袜美腿人妻连续中出-在线观看日韩三级视频| 亚洲永久免费在线观看-亚洲欧美导航一区二区导航| 韩漫一区二区在线观看-精品国产免费未成女一区二区三区| 国产综合日韩激情在线-日韩精品人妻一专区二区三区| 国产精品一区二区在线免费-久久精品国产亚洲av热明星| 亚洲精品蜜桃在线观看-国产欧美日韩在线观看精品观看| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 俄罗斯胖老太太黄色特级片-国产精品黑丝美腿美臀| 97一区二区三区在线-欧美护士性极品hd4k| 国语自产偷拍精品视频偷拍-国产伊人这里只有精品视频|