悍客電氣
主營產品: 繼電器,微機保護,直流屏等 |

悍客電氣
主營產品: 繼電器,微機保護,直流屏等 |
參考價 | 面議 |
手機/:
號:
RLJ-630F漏電繼電器相關型號
DZ-700/0004
JSMJ
JZ1-11
JX-32D
JZS-224/T
DZS-127
JY-343A
SRTD-24VDC-4H
ZJJ-1B
HJY-91B/1J
DS-27
JZB-335/002
LL-14/5
BS-62A/ⅡC
SSJ-79
JDL-22D
JL15-HS/22
JL-40B/4b
BS-142
DZ-70/J
JSM8-D5F
JYS-33
JX-322/AF
JZS-222/Q
DZS-11CE/600
JY-342E
SRTD-220VAC-4H
ZJC-3
HJY-91B/1
DS-26E
JZB-332/202
LL-13/5A
SSJ-78CD
JDL-21E
JL15-H/22
JL-40B/3a
DZ-639
JSM8-A5
JYS-13
JX-321/AT
JZS-220/7
DZS-11CE/203
JY-342A
SRTD-110VAC-4H
ZJB-220/10
HJY-91A/4D
DS-26
JZB-312/400
LL-12A
BS-62A/Ⅱ
SSJ-78BD
JDL-21A
JL15-11
JL-40B/1c
DZ-637 024(14)-2QH
JSL-64
JYB-4
JX-31A
JZS-218/Q
DZS-11B
JY-341E
SRS-DC220V-2Z
ZJ5-E
HJY-91A/3J
DS-25E
JZB-294
LL-11B
SSJ-78AD/K
JDL-13C
JL14-20J
JL-40A/6b
DZ-618/4H
JSL-37BSLT
JY-84A
BS-114A
JX-31
JZS-216
DZS-115
JY-341A
SRS-24VDC-3Z-10A
ZJ3-5E/62
HJY-91A/3
DS-25
JZB-285
LL-10
BS-62A/Ⅰ
SSJ-72B
ASJ-31A
JDL-12E
JL14-11J
JL-40A/5a
BS-141B/C
DZ-618/3H1D
JSL-25/A
JY-8-32B
JX-3/2
JZS-213/T
DZS-10B
JY-337L
SRS-220VAC-2Z-10A
RLJ-630F漏電繼電器工作原理
大容量中間繼電器為電磁式繼電器。由電磁系統(tǒng),接觸系統(tǒng)及支架三部分組成。電磁系統(tǒng)采用直動式結構,工作行程較大。接觸系統(tǒng)采用橋式觸點,斷開容量大。當線圈通電時,產生磁場,吸合鐵芯。由鐵芯帶動觸點轉換。
技術參數
1、繼電器的動合輔助觸點性能:在U≤250V時,能接通和斷開0.2A的直流無感電路或電流不超過0.5A的交流電路。
2、整定范圍:繼電器各整定點平均誤差不大于±5%。
3、溫度條件:環(huán)境溫度為-25℃~+40℃時,溫度變化對硅油粘度的影響,使繼電器的動作時間有所變化,則可調節(jié)該繼電器下端的調節(jié)螺釘,以達到特殊要求。
4、介質強度:繼電器各導電電路連在一起與外露的非帶電金屬部分及外殼之間、以及在電氣上無的不同電路之間、線圈電路與觸點電路之間,應能承受2kV(有效值)、50Hz的交流試驗電壓,歷時1min,而無絕緣擊穿或閃絡現(xiàn)象。
5、重量約為0.8kg。
6、功率消耗:不大于20VA。
7、額定頻率:50 Hz~60Hz。
8、絕緣電阻:不小于300MΩ。
9、返回時間:不大于27ms。
10、線圈溫升:當周圍環(huán)境溫度為 40℃時,其電壓繞組應能*承受110% 額定電壓,線圈溫升不超過65℃。
調試方法
動作值的檢驗
整定在2V位置時,施加100Hz電壓,調整電位器RP1使動作電壓為2V,誤差不超過5%。依次檢驗其它整定值,應能滿足誤差要求, 否則適當調整相應的整定電阻R6~R12。
動作時間的檢驗
在兩倍動作電壓下,動作時間不大于50ms。